On 4/1/22 21:04, Sean Anderson wrote:
This converts the ext load method to use spl_load. As a consequence, it
also adds support for FIT and IMX images.

Signed-off-by: Sean Anderson <sean.ander...@seco.com>

Reviewed-by: Stefan Roese <s...@denx.de>

Thanks,
Stefan

---

  common/spl/spl_ext.c | 24 +++++++++++++++++-------
  1 file changed, 17 insertions(+), 7 deletions(-)

diff --git a/common/spl/spl_ext.c b/common/spl/spl_ext.c
index ebd914c492..1384842776 100644
--- a/common/spl/spl_ext.c
+++ b/common/spl/spl_ext.c
@@ -9,6 +9,18 @@
  #include <errno.h>
  #include <image.h>
+static ulong spl_fit_read(struct spl_load_info *load, ulong file_offset,
+                         ulong size, void *buf)
+{
+       int ret;
+       loff_t actlen;
+
+       ret = ext4fs_read(buf, file_offset, size, &actlen);
+       if (ret)
+               return ret;
+       return actlen;
+}
+
  int spl_load_image_ext(struct spl_image_info *spl_image,
                       struct spl_boot_device *bootdev,
                       struct blk_desc *block_dev, int partition,
@@ -18,6 +30,10 @@ int spl_load_image_ext(struct spl_image_info *spl_image,
        struct image_header *header;
        loff_t filelen, actlen;
        struct disk_partition part_info = {};
+       struct spl_load_info load = {
+               .read = spl_fit_read,
+               .bl_len = 1,
+       };
header = spl_get_load_buffer(-sizeof(*header), sizeof(*header)); @@ -47,13 +63,7 @@ int spl_load_image_ext(struct spl_image_info *spl_image,
                goto end;
        }
- err = spl_parse_image_header(spl_image, bootdev, header);
-       if (err < 0) {
-               puts("spl: ext: failed to parse image header\n");
-               goto end;
-       }
-
-       err = ext4fs_read((char *)spl_image->load_addr, 0, filelen, &actlen);
+       err = spl_load(spl_image, bootdev, &load, header, filelen, 0);
end:
  #ifdef CONFIG_SPL_LIBCOMMON_SUPPORT

Viele Grüße,
Stefan Roese

--
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-51 Fax: (+49)-8142-66989-80 Email: s...@denx.de