On 3/24/22 10:57, Robert Marko wrote:
Update the uDPU DTS to the version that is pending upstream [1][2].

[1] 
https://patchwork.kernel.org/project/linux-arm-kernel/patch/20220322105857.1107016-1-robert.ma...@sartura.hr/
[2] 
https://patchwork.kernel.org/project/linux-arm-kernel/patch/20220322105857.1107016-2-robert.ma...@sartura.hr/

Signed-off-by: Robert Marko <robert.ma...@sartura.hr>

Applied to u-boot-marvell/master

Thanks,
Stefan
---
  arch/arm/dts/armada-3720-uDPU.dts | 21 +++++++++++++--------
  1 file changed, 13 insertions(+), 8 deletions(-)

diff --git a/arch/arm/dts/armada-3720-uDPU.dts 
b/arch/arm/dts/armada-3720-uDPU.dts
index 95d46e8d08..1f534c0c65 100644
--- a/arch/arm/dts/armada-3720-uDPU.dts
+++ b/arch/arm/dts/armada-3720-uDPU.dts
@@ -99,7 +99,7 @@
        pinctrl-names = "default";
        pinctrl-0 = <&spi_quad_pins>;
- m25p80@0 {
+       spi-flash@0 {
                compatible = "jedec,spi-nor";
                reg = <0>;
                spi-max-frequency = <54000000>;
@@ -108,10 +108,15 @@
                        compatible = "fixed-partitions";
                        #address-cells = <1>;
                        #size-cells = <1>;
-                       /* only bootloader is located on the SPI */
+
                        partition@0 {
-                               label = "uboot";
-                               reg = <0 0x400000>;
+                               label = "firmware";
+                               reg = <0x0 0x180000>;
+                       };
+
+                       partition@180000 {
+                               label = "u-boot-env";
+                               reg = <0x180000 0x10000>;
                        };
                };
        };
@@ -148,15 +153,15 @@
        scl-gpios = <&gpionb 2 (GPIO_ACTIVE_HIGH | GPIO_OPEN_DRAIN)>;
        sda-gpios = <&gpionb 3 (GPIO_ACTIVE_HIGH | GPIO_OPEN_DRAIN)>;
- lm75@48 {
+       nct375@48 {
                status = "okay";
-               compatible = "lm75";
+               compatible = "ti,tmp75c";
                reg = <0x48>;
        };
- lm75@49 {
+       nct375@49 {
                status = "okay";
-               compatible = "lm75";
+               compatible = "ti,tmp75c";
                reg = <0x49>;
        };
  };

Viele Grüße,
Stefan Roese

--
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-51 Fax: (+49)-8142-66989-80 Email: s...@denx.de

Reply via email to