On Tuesday, February 01, 2011 3:35 PM, Wolfgang Denk wrote:
> Dear "Bedia, Vaibhav",
> 
> In message
> <fccfb4cdc6e5564b9182f639fc356087035fb31...@dbde02.ent.ti.com> you
> wrote:  
>> 
>>> Luckily we don't need networking related code in SPL.
>> 
>> It might be required later on :)
> 
> It makes no sense. Load and start U-Boot if you need more fancy
> features. If you need even more complex ones (say, TCP/IP and Java
> support) then boot and OS. 
> 

I was thinking of a scenario where we have SPL being loaded over ethernet and 
the SPL stage then trying to load the 2nd stage using TFTP.

Regards,