Dear smitha.va...@wipro.com,

please stop top posting/ full quoting.  You can find hints here:
http://www.netmeister.org/news/learn2quote.html

In message <07acdfb8eca8ef47863a613bc01bbb22032bc...@hyd-mkd-mbx02.wipro.com> 
you wrote:
> 
> I get the below messages. Its failing in the fec_send BD_ENET_TX_READY
> bit is not getting set.
> Any clue?

Check your clock routing.  Eventually you have misconfigured the Tx
clock.

> > >ping 172.16.52.20
> > Using unknown device
> > ping failed; host 172.16.52.20 is not alive
> 
> Check the source code and find out why ping reports an "unknown device".

Did you solve this "unknown device" issue?  THis must be done first.

Best regards,

Wolfgang Denk

-- 