Hi Marek, Stefano,

On 02.04.2012 21:29, Marek Vasut wrote:
>> In our setup (OMAP3 EHCI host, keyboard, mouse mass storage and BT
>> dongle devices connected via several hubs) keyboard fails to initialize
>> during the bus scan (stalled endpoint while get_descriptor/64) and after
>> that keyboard is unusable (even in Linux) until power off/on.
>>
>> Increasing the delay after port reset from 200ms to 260ms solves this
>> problem.
> 
> Do we still have this problem?

Sorry, I'm not working with this board any more. I'm ccing Stefano,
probably he can answer.

Regards, Ilya.
_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot

Reply via email to