> -----Original Message----- > From: Valentin Longchamp [mailto:[email protected]] > Sent: 01 June 2012 14:33 > Cc: [email protected]; Valentin Longchamp; Holger Brunck; Prafulla > Wadaskar > Subject: [PATCH v4 1/5] kirkwood: add save functionality > kirkwood_mpp_conf function > > If a second non NULL argument is given to the kirkwood_mpp_conf > function, it will be used to store the current configuration of the > MPP > registers. mpp_save must be a preallocated table of the same size as > mpp_list and it must be zero terminated as well. > > A later call to kirkwood_mpp_conf function with this saved list as > first > (mpp_conf) argment will set the configuration back. > > Signed-off-by: Valentin Longchamp <[email protected]> > cc: Holger Brunck <[email protected]> > cc: Prafulla Wadaskar <[email protected]> > ---
Have you send just one file? I have received only one!! No Change log, pls send all files with V4 in the patch series. Regards.. Prafulla . . . _______________________________________________ U-Boot mailing list [email protected] http://lists.denx.de/mailman/listinfo/u-boot