For your information, I had to know of repeated cases where Windows 2003
cannot reboot when the "SharedSection" third parameter of the Windows
registry entry in question = 8192.
An US "U2" Technical Support Analyst told me : The quoted Technical
Bulletin is titled "Maximizing performances for UniVerse systems - updated
for UniVerse 9.5.1F"... So, theorically, the document wouldn't apply after
this (old) UniVerse release... ;-) In fact, we know that it can apply until
release 9.6.x and on Windows versions earlier than Windows 2003.
But, definitively :
- Windows 2003 manages "Desktop heap" differently than previous Windows
versions (This may have become dynamic... and... this point is not
documented by Microsoft)
- UniVerse Telnet Service at version 10.0.x have the option to "Interact
with Desktop", which makes useless for the need of the database this
Windows tuning.
- UniVerse Telnet Service + UniRPC Service at release 10.1 are both able to
"Interact with Desktop", and the need for this Windows tuning totally
disappears.
----
I answered individually to the initial message.

Regards,

Hervi BALESTRIERI
Support Technique Avanci - IBM Data Management - Produits "U2"
Web   : http://www.ibm.com/software/u2/
----- Forwarded by Herve Balestrieri/France/IBM on 23/07/2004 15:34 -----
                                                                           
             "Adrian Matthews"                                             
             <Adrian.Matthews@                                             
             igindex.co.uk>                                             To 
             Sent by:                  <[EMAIL PROTECTED]>      
             [EMAIL PROTECTED]                                          cc 
             stserver.u2ug.org                                             
                                                                   Subject 
                                       RE: [U2] UV on Win2003, refusing    
             23/07/2004 12:41          new logins, UniAdmin issues  RPC    
                                       errmsg                              
                                                                           
             Please respond to                                             
                 u2-users                                                  
                                                                           
                                                                           
                                                                           




Try this registry change using RegEdit. You won't be able to run more
than 60 sessions without this change on Windows.

"\HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control
\SessionManager\SubSystems\Windows

If the value is 1024,3072,512, change 512 to 3072."

It is in one of the UV manuals somewhere...

-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Joe Walter
Sent: 22 July 2004 18:04
To: [EMAIL PROTECTED]
Subject: [U2] UV on Win2003, refusing new logins, UniAdmin issues RPC
errmsg

This is about UV 10.1.x on Win2003 server.

I'm completely baffled by this recurring situation.

It goes like this - universe is up and running, lots of users connected,
life is
wonderful.

Sporadically - about two or three times in each
 24 hour period - the system gets into a state where it will not accept
any
 new Universe logins. Users already logged are often unaffected, but any

 attempt to start a new session with Dynamic Connect gets the message

 [Connection Aborted] right away - before telnet prompts for

 username/password are presented.

When the system is in this state, any attempt to use UniAdmin results in
an
error message something like 'RPC error 1' - I'm not sure if that is the
exact
error message, but that's the gist of it.

Tried stop/start all universe services and every time the Universe
Resource and
Universe Telnet services FAIL to restart, but the RPC service restarts
correctly.

Only way out is to reboot the server - which is a big hassle of course
and make
for very unhappy users and sysadmins ;-(

Any ideas comments on this will be highly appreciated.

Thanks much,
joe

People & Technology delivering results
http://www.ClientsFirst-US.com

Joe Walter                                  Phone-Direct   :
330.867.3851
Senior Product Engineer - Central Region    Phone-Direct   :
330.990.9081
                                            Phone-Main     :
866.732.9191
26380 Curtiss Wright Parkway, Suite 108     Fax/Voice Mail :
435.514.5132
Cleveland, OH 44143                         mailto:[EMAIL PROTECTED]
-------
u2-users mailing list
[EMAIL PROTECTED]
To unsubscribe please visit http://listserver.u2ug.org/


The information contained in this email is strictly confidential and for
the use of the addressee only, unless otherwise indicated. If you are not
the intended recipient, please do not read, copy, use or disclose to others
this message or any attachment. Please also notify the sender by replying
to this email or by telephone +44 (0)20 7896 0011 and then delete the email
and any copies of it. Opinions, conclusions (etc.) that do not relate to
the official business of this company shall be understood as neither given
nor endorsed by it.  IG Markets Limited and IG Index Plc are authorised and
regulated by the Financial Services Authority and, in Australia, by the
Australian Securities and Investments Commission.
-------
u2-users mailing list
[EMAIL PROTECTED]
To unsubscribe please visit http://listserver.u2ug.org/
-------
u2-users mailing list
[EMAIL PROTECTED]
To unsubscribe please visit http://listserver.u2ug.org/

Reply via email to