George, You have to tell your router to direct all calls to port 23 (telnet) to the internal IP address of your Windows 2003 server.
Login to your router and select the ADVANCED tab. Next, select the FORWARDING tab and make an entry that looks like this ... Ext. Port TCP UDP IP Address Enable Telnet 23 to 23 Yes No 192.168.1.201 Yes That should do it! Derek Falkner MediSolution Ltd. Kingston, Ontario, Canada -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of George Smith Sent: Tuesday, November 02, 2004 4:28 PM To: [EMAIL PROTECTED] Subject: [U2] telnet problem Hi all - need your help. I am trying to telnet to a windows 2003 machine that is running unidata 6.1 from the outside world. Having no success. Cox-internet --> static IP -> cable modem -> LinkSys BEFSR41 V3 router / hub - 3 machines One of the machines (windows 2003) has a static ip of 192.168.1.201. Can not telnet to the 192.168.1.201 from outside - can another give me the correct settings or any other help Does Unidata listern on the regular telnet port 23 ?? Thanks grs ------- u2-users mailing list [EMAIL PROTECTED] To unsubscribe please visit http://listserver.u2ug.org/ ------- u2-users mailing list [EMAIL PROTECTED] To unsubscribe please visit http://listserver.u2ug.org/