This (IMO unwanted) change in functionality occurred at 10.0. I have written a user conversion to return the time greater than 24 hours:
01: SUBROUTINE U2134(ANSWER,STATUS,DATA,CONVTYPE) 0002: * OCONV to show hours > 24 after UV10 changes hh:mm 0003: * 0004: * CATALOG AS $2134 e.g. CATALOG BP $2134 U2134 0005: * 0006: * DAN 7.5.04 0007: SECONDS = ABS(DATA) 0008: MINUTES = SECONDS / 60 0009: MINUTES += 0.5 0010: MINUTES = INT(MINUTES) 0011: HOURS = MINUTES / 60 0012: HOURS = INT(HOURS) 0013: MINUTES = MINUTES - (HOURS * 60) 0014: IF HOURS < 10 THEN HOURS = '0':HOURS 0015: ANSWER = HOURS:':':('00':MINUTES)[2] 0016: IF DATA < 0 THEN ANSWER = '-':ANSWER 0017: END HTH ======================== David Norman Senior Software Engineer SA Ambulance Service Box 3, GPO Adelaide, South Australia 5001 *+61 8 8274 0384 * fax +61 8 8271 4844 * [EMAIL PROTECTED] ------- u2-users mailing list u2-users@listserver.u2ug.org To unsubscribe please visit http://listserver.u2ug.org/