Thanks.

I should be good then. Just making sure it didn't need to be on a VAN level.

-----Original Message-----
From: u2-users-boun...@listserver.u2ug.org 
[mailto:u2-users-boun...@listserver.u2ug.org] On Behalf Of Peter S. Goldberger
Sent: Tuesday, December 31, 2013 10:56 AM
To: U2 Users List
Subject: Re: [U2] EDI Question...

ISA (IEA) and GS (GE) control numbers should be consecutive per trading 
partner. The Receiver COMM ID and the control number together are what 
the VAN looks at.


George Gallen wrote:
> The control numbers for the ISA/GS/ST segments, do they need to be unique 
> only on a trading partner scale, or on a VAN scale?
>
> So if two trading partners are going through the same VAN, can they both have 
> say a ISA control # of 00001?
>
> George Gallen
> Senior Programmer/Analyst
> Accounting/Data Division, EDI Administrator
> ggal...@wyanokegroup.com
> ph:856.848.9005 Ext 220
> The Wyanoke Group
> http://www.wyanokegroup.com<http://www.wyanokegroup.com/>
>
> _______________________________________________
> U2-Users mailing list
> U2-Users@listserver.u2ug.org
> http://listserver.u2ug.org/mailman/listinfo/u2-users
>
>
>

_______________________________________________
U2-Users mailing list
U2-Users@listserver.u2ug.org
http://listserver.u2ug.org/mailman/listinfo/u2-users
_______________________________________________
U2-Users mailing list
U2-Users@listserver.u2ug.org
http://listserver.u2ug.org/mailman/listinfo/u2-users

Reply via email to