Dont have that answer, but did find out if under power E16 you will have big issues. We had a voltage drop in the run and low output 46VDC. All 48VDC outputs worked fine, but ALL 24VDC ports would come and go!
Our solution was this: TSP-360-148 Traco PS, combined with Battery switch TSP-BCM48 for backup, added PCS-C40 120VAC breakers for protection, and on 48VDC output at battery switch we added an adjustable stepup regulator to get 56.5 VOLTS to send up tower. Small footpring, DIN RAIL Solution. Fits in a NEMA 18x18 with lots of air space available. Batteries in separate box of course. On Tue, Nov 29, 2016 at 10:10 PM, Shawn C. Peppers < videodirectwispal...@gmail.com> wrote: > Anyone know the maximum total power that the edgepoint 16 can input/output > in watts before it blows up? I am using the direct DC terminals. > > Shawn C. Peppers > Video Direct Satellite & Entertainment > 866-680-8433 Toll Free > 480-287-9960 Fax > http://www.video-direct.tv > _______________________________________________ > Ubnt_users mailing list > Ubnt_users@wispa.org > http://lists.wispa.org/mailman/listinfo/ubnt_users > -- -- Clay Stewart, COO/CTO SCS Broadband A Division of Acelanet, LLC 434.263.6363 O 434.942.6510 C cstew...@scsbroadband.com “We Keep You Up and Running” Please send sales inquiries to sa...@scsbroadband.com Please send service/repair requests to supp...@scsbroadband.com
_______________________________________________ Ubnt_users mailing list Ubnt_users@wispa.org http://lists.wispa.org/mailman/listinfo/ubnt_users