So, forgetting what the documentation says, looks like as we have 3
possible cases:

1. hwmonX contains directly the sensors data; hwmonX/device doesn't exist
2. hwmonX contains directly the sensors data; hwmonX/device exists but is 
irrelevant
3. hwmonX doesn't contain the sensors data, they are in hwmonX/device

Case 1 is covered by conky, either patched or unpatched
Case 2 would cause the unpatched conky to fail
Case 3 would cause the patched conky to fail

I can prepare a patch that covers all these cases but I can't guarantee
that this will go in before karmic is released.

** Changed in: conky (Ubuntu)
       Status: Fix Released => In Progress

** Changed in: conky (Ubuntu)
     Assignee: (unassigned) => Cesare Tirabassi (norsetto)

-- 
Conky looks in the wrong sysfs dir for hwmon temperature info