Public bug reported:

Binary package hint: gnome-power-manager

Seems to be more frequent when I am plugging in or unplugging the A/C
adapter. The battery applet displays a dead battery icon, then power-
manager window message notifies me that  battery is critically low!
without plugging in power computer will hibernate. However this is a
false message, the hardware light is blue ( signaling a fully charged
battery, and as soon as the message is closed, the battery applet
returns to the correct status). I have done my own research on google to
no availability. Most of the "fixes" were to make a script that would
run cat /proc/acpi/battery/BAT0/state and that would give power-manager
the correct info, however that is not the case. I wrote the script and
added it is a cron job / startup program, still occurs.

Lucid Lynx
Description:    Ubuntu 10.04.1 LTS
Release:        10.04

Installed: 2.30.0-0ubuntu1
Candidate: 2.30.0-0ubuntu1
Version table:
*** 2.30.0-0ubuntu1 0
500 http://us.archive.ubuntu.com/ubuntu/ lucid/main Packages
100 /var/lib/dpkg/status

ProblemType: Bug
DistroRelease: Ubuntu 10.04
Package: gnome-power-manager 2.30.0-0ubuntu1
ProcVersionSignature: Ubuntu 2.6.32-24.42-generic-pae 2.6.32.15+drm33.5
Uname: Linux 2.6.32-24-generic-pae i686
Architecture: i386
Date: Tue Sep 14 19:28:51 2010
GnomeSessionIdleInhibited: No
GnomeSessionInhibitors: 1: AppId = Transmission Bittorrent Client, Flags = 4, 
Reason = BitTorrent Activity
GnomeSessionSuspendInhibited: Yes
InstallationMedia: Ubuntu 10.04 "Lucid Lynx" - Release Candidate i386 
(20100419.1)
MachineType: Acer AO532h
ProcCmdLine: BOOT_IMAGE=/boot/vmlinuz-2.6.32-24-generic-pae 
root=UUID=8da52a81-9808-4491-b726-0066f0d59f13 ro quiet
ProcEnviron:
 LANG=en_US.utf8
 SHELL=/bin/bash
SourcePackage: gnome-power-manager
dmi.bios.date: 01/14/2010
dmi.bios.vendor: Acer
dmi.bios.version: V1.15
dmi.board.asset.tag: Base Board Asset Tag
dmi.board.name: AO532h
dmi.board.vendor: Acer
dmi.board.version: V1.15
dmi.chassis.type: 10
dmi.chassis.vendor: Acer
dmi.chassis.version: V1.15
dmi.modalias: 
dmi:bvnAcer:bvrV1.15:bd01/14/2010:svnAcer:pnAO532h:pvrV1.15:rvnAcer:rnAO532h:rvrV1.15:cvnAcer:ct10:cvrV1.15:
dmi.product.name: AO532h
dmi.product.version: V1.15
dmi.sys.vendor: Acer

** Affects: gnome-power-manager (Ubuntu)
     Importance: Undecided
         Status: New


** Tags: apport-bug i386 lucid

-- 
Constantly, but randomly, power-manager warns me that my battery is critically 
low and will be hibernating unless power is plugged in. During this I know the 
battery is 100% because when I click `OK` the battery applet then shows the 
correct information
https://bugs.launchpad.net/bugs/638592
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to