Updating the firmware on the HP Proliant DL 585 G7 server was a fairly complex operation. The following describes the steps taken by my colleague to update the firmware:
Download list: http://ftp.hp.com/pub/softlib2/software1/sc-linux-fw-array/p1997486963/v73626/CP016377.md5 http://ftp.hp.com/pub/softlib2/software1/sc-linux-fw-array/p1997486963/v73626/CP016377.scexe ftp://ftp.hp.com/pub/softlib2/software1/cd/p1040529012/v64851/firmware-9.30-0.zip ftp://ftp.hp.com/pub/softlib2/software1/sc-windows/p1576607567/v65577/cp014214.exe You will need to perform these steps on a Windows PC: 0) Download the files. 1) Extract firmware-9.30-0.zip. 2) Use cp014214.exe to create a bootable USB key, from the iso file in firmware-9.30-0.zip. 3) copy CP016377.md5 and CP016377.scexe to /HPFWUP9xx/hp/swpackages on the USB key. You do these steps on the server: 4) Boot on the USB key. 5) Switch to another console (alt+F1). 6) Execute CP016377.scexe. -- You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. https://bugs.launchpad.net/bugs/969304 Title: Regression: Missing Firmware Files phanfw.bin and nx3fwct.bin (precise 12.04 beta) To manage notifications about this bug go to: https://bugs.launchpad.net/ubuntu/+source/linux-firmware/+bug/969304/+subscriptions -- ubuntu-bugs mailing list ubuntu-bugs@lists.ubuntu.com https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs