Updating the firmware on the HP Proliant DL 585 G7 server was a fairly
complex operation. The following describes the steps taken by my
colleague to update the firmware:

Download list:
http://ftp.hp.com/pub/softlib2/software1/sc-linux-fw-array/p1997486963/v73626/CP016377.md5
http://ftp.hp.com/pub/softlib2/software1/sc-linux-fw-array/p1997486963/v73626/CP016377.scexe
ftp://ftp.hp.com/pub/softlib2/software1/cd/p1040529012/v64851/firmware-9.30-0.zip
ftp://ftp.hp.com/pub/softlib2/software1/sc-windows/p1576607567/v65577/cp014214.exe

You will need to perform these steps on a Windows PC:
0) Download the files.
1) Extract firmware-9.30-0.zip.
2) Use cp014214.exe to create a bootable USB key, from the iso file in 
firmware-9.30-0.zip.
3) copy CP016377.md5 and CP016377.scexe to /HPFWUP9xx/hp/swpackages on the USB 
key.

You do these steps on the server:
4) Boot on the USB key.
5) Switch to another console (alt+F1).
6) Execute CP016377.scexe.

-- 