On 2012-05-10T07:06:46-0000, Alex Popovskiy <997...@bugs.launchpad.net> wrote: > munin plugin sensors_ broken, throws errors like this: > 2012/05/10-10:00:04 [29737] Error output from sensors_fans: > 2012/05/10-10:00:04 [29737] Use of uninitialized value in concatenation > (.) or string at /etc/munin/plugins/sensors_fans line 266. > 2012/05/10-10:00:04 [29737] Use of uninitialized value in concatenation > (.) or string at /etc/munin/plugins/sensors_fans line 267. > 2012/05/10-10:00:04 [29737] Use of uninitialized value in concatenation > (.) or string at /etc/munin/plugins/sensors_fans line 268. > 2012/05/10-10:00:04 [29737] Use of uninitialized value in regexp > compilation at /etc/munin/plugins/sensors_fans line 272. > 2012/05/10-10:00:04 [29737] Error output from sensors_fans: > 2012/05/10-10:00:04 [29737] Use of uninitialized value in regexp > compilation at /etc/munin/plugins/sensors_fans line 284. > 2012/05/10-10:00:04 [29737] Error output from sensors_temperatures: > 2012/05/10-10:00:04 [29737] Use of uninitialized value in concatenation > (.) or string at /etc/munin/plugins/sensors_temperatures line 266. > 2012/05/10-10:00:04 [29737] Use of uninitialized value in concatenation > (.) or string at /etc/munin/plugins/sensors_temperatures line 267. > 2012/05/10-10:00:04 [29737] Use of uninitialized value in concatenation > (.) or string at /etc/munin/plugins/sensors_temperatures line 268. > 2012/05/10-10:00:04 [29737] Use of uninitialized value in regexp > compilation at /etc/munin/plugins/sensors_temperatures line 272. > 2012/05/10-10:00:04 [29737] Error output from sensors_temperatures: > 2012/05/10-10:00:04 [29737] Use of uninitialized value in regexp > compilation at /etc/munin/plugins/sensors_temperatures line 284.
The problem here is that you're using the plugin incorrectly. The only possible wildcard values are these: temp, fan, volt. So the symlinks should be sensors_fan, sensors_temp, and sensors_volt. I've added some text to the plugin's documentation clarifying this in upstream changeset 4854: http://munin-monitoring.org/changeset/4854 I also enhanced the plugin in changeset 4856 to get the warning and critical values from sensors output like yours. I've tested that the plugin works correctly with your sensors output, provided you use the correct symlinks. -- Kenyon Ralph ** Changed in: munin (Ubuntu) Status: In Progress => Fix Committed ** Changed in: munin (Ubuntu) Status: Fix Committed => Invalid -- You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. https://bugs.launchpad.net/bugs/997497 Title: sensors plugin does not recognize sensors output To manage notifications about this bug go to: https://bugs.launchpad.net/ubuntu/+source/munin/+bug/997497/+subscriptions -- ubuntu-bugs mailing list ubuntu-bugs@lists.ubuntu.com https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs