Public bug reported:

The current temperature is reported as 49 Celcius

On producer specifies an operation range of 0 - 70 Celcius

The disk is new , with disk utility reporting 2 hours of power on.

Here is the output from smartctl

adi@pp:~$ sudo smartctl --all /dev/sda
smartctl 5.41 2011-06-09 r3365 [i686-linux-3.2.0-31-generic-pae] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     KINGSTON SV200S3128G
Serial Number:    22RA30NYKAWK
Firmware Version: E120506a
User Capacity:    128,035,676,160 bytes [128 GB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   9
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Sun Sep 30 10:04:54 2012 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      ( 249) Self-test routine in progress...
                                        90% of test remaining.
Total time to complete Offline 
data collection:                (   32) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off 
support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (   1) minutes.
SCT capabilities:              (0x0039) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000a   100   100   000    Old_age   Always       
-       0
  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      
-       0
  3 Spin_Up_Time            0x0007   100   100   050    Pre-fail  Always       
-       0
  5 Reallocated_Sector_Ct   0x0013   100   100   050    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x000b   100   100   050    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0005   100   100   050    Pre-fail  Offline      
-       0
  9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       
-       2
 10 Spin_Retry_Count        0x0013   100   100   050    Pre-fail  Always       
-       0
 12 Power_Cycle_Count       0x0012   100   100   000    Old_age   Always       
-       12
167 Unknown_Attribute       0x0022   100   100   000    Old_age   Always       
-       0
168 Unknown_Attribute       0x0012   100   100   000    Old_age   Always       
-       2
169 Unknown_Attribute       0x0013   100   100   010    Pre-fail  Always       
-       0
173 Unknown_Attribute       0x0012   200   200   000    Old_age   Always       
-       0
175 Program_Fail_Count_Chip 0x0013   100   100   010    Pre-fail  Always       
-       0
192 Power-Off_Retract_Count 0x0012   100   100   000    Old_age   Always       
-       0
194 Temperature_Celsius     0x0023   045   045   030    Pre-fail  Always       
-       45 (Min/Max 30/45)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       
-       0
240 Head_Flying_Hours       0x0013   100   100   050    Pre-fail  Always       
-       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Self-test routine in progress 00%         2         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

ProblemType: Bug
DistroRelease: Ubuntu 12.04
Package: gnome-disk-utility 3.0.2-2ubuntu7
ProcVersionSignature: Ubuntu 3.2.0-31.50-generic-pae 3.2.28
Uname: Linux 3.2.0-31-generic-pae i686
NonfreeKernelModules: wl
ApportVersion: 2.0.1-0ubuntu13
Architecture: i386
Date: Sun Sep 30 10:08:04 2012
InstallationMedia: Ubuntu 12.04.1 LTS "Precise Pangolin" - Release i386 
(20120817.3)
SourcePackage: gnome-disk-utility
UpgradeStatus: No upgrade log present (probably fresh install)

** Affects: gnome-disk-utility (Ubuntu)
     Importance: Undecided
         Status: New


** Tags: apport-bug i386 precise running-unity

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1058932

Title:
  SSD temperature - disk is being use outside of designed parameters

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/gnome-disk-utility/+bug/1058932/+subscriptions

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to