Laptop is HP Probook 4540s with Seagate 750GB HDD.

smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-24-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Momentus SpinPoint M8 (AF)
Device Model:     ST750LM022 HN-M750MBB
Serial Number:    S2SUJ9KC909317
LU WWN Device Id: 5 0004cf 2085c649e
Firmware Version: 2AR10002
User Capacity:    750,156,374,016 bytes [750 GB]
Sector Sizes:     512 bytes logical, 4096 bytes physical
Rotation Rate:    5400 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Tue May  6 13:53:33 2014 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                ( 9780) seconds.
Offline data collection
capabilities:                    (0x51) SMART execute Offline immediate.
                                        No Auto Offline data collection support.
                                        Suspend Offline collection upon new
                                        command.
                                        No Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        ( 163) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  
WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   051    Pre-fail  Always       
-       13
  2 Throughput_Performance  0x0027   252   252   000    Pre-fail  Always       
-       0
  3 Spin_Up_Time            0x0023   089   089   025    Pre-fail  Always       
-       3456
  4 Start_Stop_Count        0x0032   099   099   000    Old_age   Always       
-       1233
  5 Reallocated_Sector_Ct   0x0033   252   252   010    Pre-fail  Always       
-       0
  7 Seek_Error_Rate         0x002f   252   252   051    Pre-fail  Always       
-       0
  8 Seek_Time_Performance   0x0025   252   252   015    Pre-fail  Offline      
-       0
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       
-       4116
 10 Spin_Retry_Count        0x0033   252   252   051    Pre-fail  Always       
-       0
 11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       
-       409
 12 Power_Cycle_Count       0x0032   099   099   000    Old_age   Always       
-       1204
181 Program_Fail_Cnt_Total  0x0022   100   100   000    Old_age   Always       
-       9806512
183 Runtime_Bad_Block       0x0032   252   252   010    Old_age   Always       
-       0
184 End-to-End_Error        0x0033   252   252   048    Pre-fail  Always       
-       0
186 Unknown_Attribute       0x0032   252   252   000    Old_age   Always       
-       0
187 Reported_Uncorrect      0x0032   252   252   000    Old_age   Always       
-       0
188 Command_Timeout         0x0032   252   252   000    Old_age   Always       
-       0
190 Airflow_Temperature_Cel 0x0002   074   056   040    Old_age   Always       
-       26 (Min/Max 15/45)
191 G-Sense_Error_Rate      0x0022   100   100   000    Old_age   Always       
-       63
192 Power-Off_Retract_Count 0x0022   252   252   000    Old_age   Always       
-       0
193 Load_Cycle_Count        0x0032   091   091   000    Old_age   Always       
-       92145
194 Temperature_Celsius     0x0002   064   056   000    Old_age   Always       
-       26 (Min/Max 15/45)
195 Hardware_ECC_Recovered  0x003a   100   100   000    Old_age   Always       
-       0
196 Reallocated_Event_Count 0x0032   252   252   000    Old_age   Always       
-       0
197 Current_Pending_Sector  0x0032   252   252   000    Old_age   Always       
-       0
198 Offline_Uncorrectable   0x0030   252   252   000    Old_age   Offline      
-       0
199 UDMA_CRC_Error_Count    0x0036   200   200   000    Old_age   Always       
-       0
200 Multi_Zone_Error_Rate   0x002a   100   100   000    Old_age   Always       
-       7281

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  
LBA_of_first_error
# 1  Short offline       Completed without error       00%      4110         -
# 2  Short offline       Completed without error       00%      4108         -
# 3  Short offline       Completed without error       00%      4104         -

SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been 
run
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Completed [00% left] (0-65535)
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


///////////////////////////////////////////////////////////////////////////////////////////////////////////
Last night I noticed that cycles are now getting higher even with AC.
On Windows this is not happening on the AC or battery.

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1316284

Title:
  Load/Unload Cycle Count

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1316284/+subscriptions

-- 