I have verified ironic-conductor ipmitool commands behaviour with the
above PPA in #2 (On focal ussuri)


With configuration use_ipmitool_retries = False, ironic-conductor runs below 
command until 60 seconds timeout expiry.
Command: ipmitool -I lanplus -H 10.5.0.5:9999 -L ADMINISTRATOR -U test -R 1 -N 
5 -f /tmp/tmpmt5292he power status

OpenStack commands used for testing:
/snap/bin/openstack baremetal node create --driver ipmi --driver-info 
ipmi_address=10.5.0.5:9999 --driver-info ipmi_username=test --driver-info 
ipmi_password=test
/snap/bin/openstack baremetal node list
/snap/bin/openstack baremetal node power on <node id>

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1943765

Title:
  ipmitool "timing" flags are not working as expected causing failure to
  manage power of baremetal nodes