The culprit here is that there is no timeout on the serial console read/write.
>From cloudinit/cs_utils.py 73 def __init__(self, request): 74 self.request = request 75 self.raw_result = self._execute() 76 self.result = self._marshal(self.raw_result) 77 78 def _execute(self): 79 connection = serial.Serial(SERIAL_PORT) 80 connection.write(self.request) 81 return connection.readline().strip('\x04\n') Further, since we are blocking on the serial port, I have to question whether or not this should be a default enabled source. The other serial terminal DS is SmartOS, which is disabled by default. There are a lot of good reasons why people attach serial consoles, but assuming that it safe for cloud-init to read/write to a serial console seems like a great way to break infrastructure or control planes. IMHO, I think that the fix should be twofold 1) disable this ds by default; 2) enforce a reasonable time out. I've attached a rough patch of what I am thinking here. We should get CloudSigma to clarify what the timeout should be before we enforce the timeout. That said, I think that an SRU that disables the DS is warranted. ** Patch added: "Make CloudSigma datasource timeout on serial console" https://bugs.launchpad.net/cloud-init/+bug/1316475/+attachment/4120172/+files/lp1316475.patch ** Branch linked: lp:~utlemming/cloud-init/cloudsigma_ds.1316475 -- You received this bug notification because you are a member of Ubuntu Server Team, which is subscribed to cloud-init in Ubuntu. https://bugs.launchpad.net/bugs/1316475 Title: trusty hang on first boot post deploy To manage notifications about this bug go to: https://bugs.launchpad.net/cloud-init/+bug/1316475/+subscriptions -- Ubuntu-server-bugs mailing list Ubuntu-server-bugs@lists.ubuntu.com Modify settings or unsubscribe at: https://lists.ubuntu.com/mailman/listinfo/ubuntu-server-bugs