On 3/29/22 20:10, Farhan Khan wrote:
Hi all,

I am trying to send the initial "wakeup" USB Rx interrupt packet via 
usbd_transfer_start(), but after running the callback with USB_ST_SETUP, I receive 
another callback with USB_ERR_CANCELLED as the value of usb_error_t. What might be 
causing the cancellation?

Detailed explanation:
I am opening the pipes, then immediately running usbd_transfer_start() on the 
Rx Interrupt with this:
usbd_transfer_start(usc->usc_xfer[ATHN_RX_INTR]);

The callback function runs this:

        case USB_ST_SETUP:
                usbd_xfer_set_frame_len(xfer, 0, usbd_xfer_max_len(xfer));
                usbd_transfer_submit(xfer);
                break;

The next time the callback is invoked, the USB_GET_STATE macro reports 
USB_ST_ERROR with the value being USB_ERR_CANCELLED. The manual page suggests 
that this is the result of a transfer currently happening, but I am not clear 
on the issue. I have both set and disabled pipe_bof on the Rx Interrupt with 
the same result.

I borrowed the above code from the otus(4) driver.

Please assist. Thanks!

Something in your code is calling usbd_transfer_stop() or unsetup().

--HPS