You don't need to change the number of vnodes, you can manually select
CONTAINED token subranges and pass in -st and -et (just try to pick a
number > 2^20 that is fully contained by at least one vnode).




On Wed, Oct 4, 2017 at 9:46 AM, Mohapatra, Kishore <
kishore.mohapa...@nuance.com> wrote:

> Hi,
>
>         We are having a lot of problems in repair process. We use sub
> range repair. But most of the time, some ranges fails with streaming error
> or some other kind of error.
>
> So wondering if it will help if we increase the no. of VNodes from 256
> (default) to 512. But increasing the VNodes will be a lot of efforts, as it
> involves wiping out the data and bootstrapping.
>
> So is there any other way of splitting the range into small ranges ?
>
>
>
> We are using version 2.1.15.4 at the moment.
>
>
>
> Thanks
>
>
>
> *Kishore Mohapatra*
>
> Principal Operations DBA
>
> Seattle, WA
>
> Email : kishore.mohapa...@nuance.com
>
>
>
>
>

Reply via email to