You don't need to change the number of vnodes, you can manually select CONTAINED token subranges and pass in -st and -et (just try to pick a number > 2^20 that is fully contained by at least one vnode).
On Wed, Oct 4, 2017 at 9:46 AM, Mohapatra, Kishore < kishore.mohapa...@nuance.com> wrote: > Hi, > > We are having a lot of problems in repair process. We use sub > range repair. But most of the time, some ranges fails with streaming error > or some other kind of error. > > So wondering if it will help if we increase the no. of VNodes from 256 > (default) to 512. But increasing the VNodes will be a lot of efforts, as it > involves wiping out the data and bootstrapping. > > So is there any other way of splitting the range into small ranges ? > > > > We are using version 2.1.15.4 at the moment. > > > > Thanks > > > > *Kishore Mohapatra* > > Principal Operations DBA > > Seattle, WA > > Email : kishore.mohapa...@nuance.com > > > > >