Hi,Jiazhi

>         When DataStream is converted to table, eventTime is converted to 
> rowTime. Rowtime is 8 hours slow. How to solve this problem?

The reason is that the only data type that used to define an event time in 
Table/SQL is TIMESTAMP(3), and TIMESTAMP type isn’t related to your local time 
zone(UTC+8) which caused the timezone problem. You can workaround this by 
converting your TIMESTAMP with your timezone offset before query start and 
convert the TIMESTAMP back after query end.

And I think the best way to resolve this problem is to support defining event 
time on data type TIMESTAMP WITH LOCAL TIME ZONE, this is a known issue and the 
roadmap which we hope to improve it in Flink 1.13.


Best,
Leonard