I found the problem.  I tried to sign timestamps to the operator (I don't
know why), and when I did that, because I used the Flink API fluently, I
was no longer referencing the operator that contained the side-outputs.

Disregard my question.

On Sat, May 22, 2021 at 9:28 PM Marco Villalobos <mvillalo...@kineteque.com>
wrote:

> I have been struggling for two days with an issue using the DataStream API
> in Batch Execution mode.
>
> It seems as though my side-output has no elements available to downstream
> operators.
> However, I am certain that the downstream operator received events.
>
> I logged the side-output element just before it was collected.  There are
> no exceptions in the logs.
>
> However, everytime I run the job the side-output appears empty.
>
> I noticed https://issues.apache.org/jira/browse/FLINK-20517
>
> So, I keyed my output tag immediately after retrieving it, and that also
> did not help.
>
> Any advice or information on this would be appreciated.
>
> Thank you.
>

Reply via email to