Hi Ankit,

If shared memory library is not loaded, nodes will simply switch to TCP and
everything will work fine. Actually, shared memory communication is known to
be not very stable, so usually we recommend to disable it. Most likely it
will not be default anymore in 2.0, or probably will be even removed
completely.

-Val



--
View this message in context: 
http://apache-ignite-users.70518.x6.nabble.com/WARNING-Failed-to-load-igniteshmem-library-from-classpath-Will-try-to-load-it-from-IGNITE-HOME-WARNI-tp9715p9722.html
Sent from the Apache Ignite Users mailing list archive at Nabble.com.