Hi,

The method will be invokes in server side, but only on particular nodes
(where the data entry will be stored). The batch of data will be submit to
receiver when the buffer (DataStreamer#perNodeBufferSize()) is full of got a
time of do that by frequency (DataStreamer#autoFlushFrequency()) or you have
manual invoked DataStreamer#flush or DataStreamer#close the streamer.




--
View this message in context: 
http://apache-ignite-users.70518.x6.nabble.com/How-to-debug-a-method-in-a-streamer-s-receiver-method-tp13273p13311.html
Sent from the Apache Ignite Users mailing list archive at Nabble.com.