I have only 3 nodes, in three separate physical boxes. Question is, can there 
be any possibility for creating such number of sockets on 47500, between two 
nodes ? I cannot reproduce the issue. Hence trying to find any theoretical 
possibility.



-----Original Message-----
From: dkarachentsev [mailto:dkarachent...@gridgain.com] 
Sent: Tuesday, June 12, 2018 11:37 AM
To: user@ignite.apache.org
Subject: RE: Ignite opens/close 5000 sockets in every 5mins after NODE_FAILED 
event

There is no difference on how do you start/stop your node. 
Node on start will examine all connections specified in address list: it
takes one address and port and tries to connect to it. If not successfull,
get another address and port. For instance if you have address
1.2.3.4:47500..47509, node will check 10 addresses.

Does this impact you somehow?

Thanks!
-Dmitry



--
Sent from: http://apache-ignite-users.70518.x6.nabble.com/

Reply via email to