Hi,

yes I tried and I got the same error.

On Thu, Aug 30, 2018 at 6:33 PM Ilya Kasnacheev <ilya.kasnach...@gmail.com>
wrote:

> Hello!
>
> Have you tried Ignition::StopAll(false); ?
>
> Regards,
> --
> Ilya Kasnacheev
>
>
> чт, 30 авг. 2018 г. в 13:04, F.D. <free.devel...@gmail.com>:
>
>> Hi Igniters,
>>
>> when in my c++ client I close the connection to the server, after a
>> computation, I got this error:
>>
>> [11:29:51,542][SEVERE][grid-nio-worker-tcp-comm-1-#34][TcpCommunicationSpi]
>> Failed to process selector key
>> [...]
>> java.io.IOException: An existing connection was forcibly closed by the
>> remote host                              at
>> sun.nio.ch.SocketDispatcher.read0(Native Method)
>>                                         at
>> sun.nio.ch.SocketDispatcher.read(SocketDispatcher.java:43)
>>                                   at
>> sun.nio.ch.IOUtil.readIntoNativeBuffer(IOUtil.java:223)
>>                                           at
>> sun.nio.ch.IOUtil.read(IOUtil.java:192)
>>                                                     at
>> sun.nio.ch.SocketChannelImpl.read(SocketChannelImpl.java:380)
>>                               at
>> org.apache.ignite.internal.util.nio.GridNioServer$DirectNioClientWorker.processRead(GridNioServer.java:1250)
>>
>>         at
>> org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.processSelectedKeysOptimized(GridNioServer.java:2339)
>>
>>         at
>> org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.bodyInternal(GridNioServer.java:2110)
>>
>>         at
>> org.apache.ignite.internal.util.nio.GridNioServer$AbstractNioClientWorker.body(GridNioServer.java:1764)
>>
>>         at
>> org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:110)
>>                              at java.lang.Thread.run(Thread.java:748)
>>
>>
>> To close the client I use this statment:
>>       Ignition::StopAll(true);
>>
>> Is it possibile to avoid this error?
>>
>> Thanks,
>>   F.D.
>>
>>

Reply via email to