Hello! There is a ticket to make those messages more clear: https://issues.apache.org/jira/browse/IGNITE-10760
Regards, -- Ilya Kasnacheev пт, 21 дек. 2018 г. в 11:31, [email protected] <[email protected]>: > Thanks for clarify! > > Regards > Aaron > > > *From:* Loredana Radulescu Ivanoff <[email protected]> > *Date:* 2018-12-21 02:40 > *To:* user <[email protected]> > *Subject:* Re: Re: Partition-exchanger blocked after upgrade to 2.7 > Hello, > > We've been witnessing a similar set of logs from Apache Ignite after > upgrading to 2.7 (from 2.6) in a couple of different environments, one of > which had only one Ignite node. Very frequently, ignite will log the > message "Blocked system-critical thread has been detected. This can lead to > cluster-wide undefined behaviour [threadName=partition-exchanger, > blockedFor=13s]" and write a full thread dump. An examination of the thread > dump does not seem to indicate any specific threads that are actually > blocked or delayed. We do not appear to have any cluster wide issues > despite the logging. > In our understanding the sysWorkerBlockedTimeout property defaults to > DFLT_FAILURE_DETECTION_TIMEOUT. We have the failure detection timeout > configured to 10s. > We do not have a solution for it so far. > > On Thu, Dec 20, 2018 at 7:34 AM ilya.kasnacheev <[email protected]> > wrote: > >> Hello! >> >> Do you have any non-standard settings for failureDetectionTimeout or >> networkTimeout? >> >> Do you have any observable issues besides occasional extra logging? >> >> Regards, >> >> >> >> -- >> Sent from: http://apache-ignite-users.70518.x6.nabble.com/ >> >