Gentle reminder.

On Tue, 20 Dec 2022, 12:53 Surinder Mehra, <[email protected]> wrote:

> Hi,
> If we have cache synchronization mode as Primary Sync and read from backup
> as true(default), would this cause consistency issues if primary goes down
> without flushing all data to disk.
> I understand WAL is used to replay unflushed data when a node comes back
> online again. But if say out of 10 records written to cache, only 5 of them
> were written to disk by checkpointing thread and data was not replicated to
> the backup node yet(PRIMARY-SYNC) when primary node went node, the client
> would assume backup node would have all 10 records . But it might not be
> the case.
>
> So am I correct in assuming we need to either turn off read from backup or
> change cache synchronization mode to FULL-SYNC
>
> Answer to stackoverflow question below suggests disabling read from
> backup. Do we need to disable it even in FULL-SYNC mode ?
>
>
> https://stackoverflow.com/questions/67598175/ignite-read-stale-data-from-backup-node
>

Reply via email to