Hi, Thank you Stephen and Pavel. I will try these options and keep you posted.
Regards, Charlin On Thu, 12 Jan 2023 at 17:45, Pavel Tupitsyn <[email protected]> wrote: > Set different client connector ports for different grids like this: > > <bean class="org.apache.ignite.configuration.IgniteConfiguration"> > <property name="clientConnectorConfiguration"> > <bean > class="org.apache.ignite.configuration.ClientConnectorConfiguration"> > <property name="port" value="10900"/> > </bean> > </property> > ... > > On Thu, Jan 12, 2023 at 2:01 PM Stephen Darlington < > [email protected]> wrote: > >> Those ports are for thick-clients and servers. Thin clients connect to >> 10800. The second server to start will be on 10801, etc. >> >> You can configure the thin-client port with ClientConnectorConfiguration: >> getting-started-with-thin-clients >> <https://ignite.apache.org/docs/latest/thin-clients/getting-started-with-thin-clients#configuring-thin-client-connector> >> >> On 12 Jan 2023, at 11:56, Charlin S <[email protected]> wrote: >> >> Hi Pavel, >> Thanks for your reply. >> I am having two grids in one server and grid configuration as below. >> Which port should I use for connecting grid1 and grid2? >> >> <image.png> >> >> As per my understanding, I should be able to connect thin clients like >> this. Please correct me if I am wrong. >> >> //for Grid 1 >> >> var clientCfgGrid1 = new IgniteClientConfiguration >> { >> Endpoints = new[] { "10.201.30.116: >> <http://127.0.0.1:10901/>48500","10.201.30.117: >> <http://127.0.0.1:10901/>48500" } >> >> }; >> >> // for Grid 2 >> >> var clientCfgGrid2 = new IgniteClientConfiguration >> { >> Endpoints = new[] { "10.201.30.116: >> <http://127.0.0.1:10901/>55800","10.201.30.117: >> <http://127.0.0.1:10901/>55800" } >> >> }; >> >> >> Regards, >> Charlin >> >> >> >> >> >> >> >> >> >> On Thu, 12 Jan 2023 at 15:37, Pavel Tupitsyn <[email protected]> >> wrote: >> >>> >>> C# thin client can connect to any port, specify it in the endpoint >>> string like this: >>> >>> var clientCfg = new IgniteClientConfiguration("127.0.0.1:10901"); >>> var client = Ignition.StartClient(clientCfg); >>> >>> >>> or >>> >>> var clientCfg2 = new IgniteClientConfiguration >>> { >>> Endpoints = new[] { "127.0.0.1:10901" } >>> }; >>> >>> >>> On Thu, Jan 12, 2023 at 11:41 AM Charlin S <[email protected]> >>> wrote: >>> >>>> Hi All, >>>> My requirement is to connect a specific grid(server has multiple grids) >>>> from c# thin client, since its support only 10800 ports. >>>> >>>> Regards, >>>> Charlin >>>> >>>> >>>> >>>> >>