Hello Ignite community. I started three ignite nodes, but after a while, there are a lot of the following content :
Line 20658: [17:07:01,115][WARNING][grid-nio-worker-client-listener-0-#33][ClientListenerProcessor] Client disconnected abruptly due to network connection loss or because the connection was left open on application shutdown. [cls=classo.a.i.i.util.nio.GridNioException, msg=Connection reset] Line 20669: [17:07:02,114][WARNING][grid-nio-worker-client-listener-1-#34][ClientListenerProcessor] Client disconnected abruptly due to network connection loss or because the connection was left open on application shutdown. [cls=classo.a.i.i.util.nio.GridNioException, msg=Connection reset]" in the log. Why is this? What impact do these logs have? 2. Occasionally, it will appear " ---> System.Net.Sockets.SocketException (10060): at System.Net.Sockets.NetworkStream.Read(Byte[] buffer, Int32 offset, Int32 count) --- End of inner exception stack trace --- at System.Net.Sockets.NetworkStream.Read(Byte[] buffer, Int32 offset, Int32 count) at Apache.Ignite.Core.Impl.Client.ClientSocket.SocketRead(Byte[] buf, Int32 pos, Int32 len) at Apache.Ignite.Core.Impl.Client.ClientSocket.ReceiveBytes(Int32 size) at Apache.Ignite.Core.Impl.Client.ClientSocket.ReceiveMessage() at Apache.Ignite.Core.Impl.Client.ClientSocket.SendRequest(RequestMessage& reqMsg) at Apache.Ignite.Core.Impl.Client.ClientSocket.DoOutInOp[T](ClientOp opId, Action1 writeAction, Func2 readFunc, Func`3 errorFunc) at Apache.Ignite.Core.Impl.Client.ClientFailoverSocket.DoOutInOp[T](ClientOp opId, Action1 writeAction, Func2 readFunc, Func`3 errorFunc) at Apache.Ignite.Core.Impl.Client.IgniteClient.GetOrCreateCache[TK,TV](String name) at Aurora.Server.IgniteDBProxy.SaveToCache(String cacheName, String key, Object obj) in e:\Code\ProjectG_SVN\Server_Change\Code\Src\Common\DB\IgniteDBProxy.cs:line 37 at Aurora.Server.IgniteHelper.SaveObjToIgnite(IgniteDBProxy igniteDBProxy, String key, Object obj) in e:\Code\ProjectG_SVN\Server_Change\Code\Src\Common\DB\IgniteHelper.cs:line 31 at Aurora.Game.PlayerDBComponentSystem.SaveAllHumanDataToDB(PlayerDBComponent self) in e:\Code\ProjectG_SVN\Server_Change\Code\Src\Server\Components\PlayerDBComponent.cs:line 115 at Aurora.Game.PlayerDBComponentSystem.Update(PlayerDBComponent self) in e:\Code\ProjectG_SVN\Server_Change\Code\Src\Server\Components\PlayerDBComponent.cs:line 51 at Aurora.Framework.SystemCallback`1.Invoke(Entity comp) in e:\Code\ProjectG_SVN\Framework\Framework\Src\Framework\Interface\IComponent.cs:line 63 at Aurora.Framework.EntitySystem.Update(Int32 deltaTimeMs) in e:\Code\ProjectG_SVN\Framework\Framework\Src\Framework\Entity\EntitySystem.cs:line 579, " why is this? Note : The thin client and ignite node are in the same network segment of the intranet. ignite version: 2.14 thin client: .net My application is multi-threaded, and I have established a thin client pool (since Ignite thin client is thread-safe, so I did this). Have a beautiful day. Yours sincerely Zhou Chen