no, if the trafic is one way, producer to ha pair, a network bridge
just on the embedded producer broker is suffice.

you say that the consumers don't get messages when the ha pair master
is stopped.
Are the consumers using failover: with both master and slave urls present?
do you see the connection drop and get auto reconnected to the slave?
How are the consumers configured?


On 8 May 2012 18:09, pollotek <claudio.sant...@gmail.com> wrote:
> Gary, do you  mean pointing the master slave brokers back at the embedded
> broker? I already have the embedded broker pointing at both master and slave
> with static failover.
>
> --
> View this message in context: 
> http://activemq.2283324.n4.nabble.com/Embedded-broker-to-master-slave-topologies-not-working-on-failover-tp4615643p4618087.html
> Sent from the ActiveMQ - User mailing list archive at Nabble.com.



-- 
http://fusesource.com
http://blog.garytully.com

Reply via email to