Hi Shanker,

Aww.. VLAN ID information for Public network provided to me was
incorrected.

Just for Information..

I have xen setup to isolate primary storage traffic, where Cloudstack MS &
Secondary storage is on same NIC & primary storage is on separate NIC,
secondary storage traffic is moving from management NIC.

 For testing purpose I am planning to implement swift as secondary sorage,
So is there any way i can isolate secondary storage traffic from management
NIC.

Regards,
Tejas


Regards,
Tejas



On Thu, Jun 5, 2014 at 3:48 PM, Shanker Balan <shanker.ba...@shapeblue.com>
wrote:

> Comments inline.
>
> On 05-Jun-2014, at 3:02 pm, Tejas Gadaria <refond.g...@gmail.com> wrote:
>
> > Hi Shanker,
> >
> > 1) Also I am not able to ping to gateway.
>
>
> Not good.
>
> > 2) Here is the ssvm-check output..
> >
> > root@s-1-VM:/usr/local/cloud/systemvm# sh ssvm-check.sh
> > ================================================
> > First DNS server is  8.8.8.8
> > PING 8.8.8.8 (8.8.8.8): 48 data bytes
> > 56 bytes from 8.8.8.8: icmp_seq=0 ttl=46 time=62.104 ms
> > 56 bytes from 8.8.8.8: icmp_seq=1 ttl=46 time=62.306 ms
> > --- 8.8.8.8 ping statistics ---
> > 2 packets transmitted, 2 packets received, 0% packet loss
> > round-trip min/avg/max/stddev = 62.104/62.205/62.306/0.101 ms
> > Good: Can ping DNS server
> > ================================================
> > Good: DNS resolves download.cloud.com
> > ================================================
> > nfs is currently mounted
> > Mount point is /mnt/SecStorage/fde1faee-5559-3165-82a8-0078c7b99c08
> > Good: Can write to mount point
> > ================================================
> > Management server is 10.129.151.55. Checking connectivity.
> > Good: Can connect to management server port 8250
> > ================================================
> > Good: Java process is running
> > ================================================
> > Tests Complete. Look for ERROR or WARNING above.
> >
> >
> > But in ssvm /var/log/cloud/cloud.out i found below logs.
> >
> > 06:41:01,502  INFO NioClient:81 - Connected to 10.129.151.55:8250
> > 06:41:01,681  INFO Agent:421 - Proccess agent startup answer, agent id =
> 0
> > 06:41:01,681  INFO Agent:267 - Set agent id 0
> > 06:41:01,699  INFO Agent:431 - Startup Response Received: agent id = 0
> > 06:41:01,741  INFO NfsSecondaryStorageResource:2482 - Determined host
> > 10.129.155.101 corresponds to IP 10.129.155.101
> > 06:41:01,742  INFO NfsSecondaryStorageResource:2482 - Determined host
> > 10.129.155.101 corresponds to IP 10.129.155.101
> > 06:41:03,954  INFO NfsSecondaryStorageResource:2482 - Determined host
> > 10.129.155.101 corresponds to IP 10.129.155.101
> > 06:43:12,830 ERROR NfsSecondaryStorageResource:2396 - Unable to mount
> > 10.129.155.101:/vol/secondary at
> > /mnt/SecStorage/548477a5-73f6-3dd6-9179-93e4c92a3329 due to mount.nfs:
> > Connection timed out
> >
>
>
> ssvm-check and logs dont seem to agree on the secondary storage.
>
> > nfs is currently mounted
> > Mount point is /mnt/SecStorage/fde1faee-5559-3165-82a8-0078c7b99c08
> > Good: Can write to mount point
>
> ssvm-check says it can write to the mount point.
>
> > 06:43:12,830 ERROR NfsSecondaryStorageResource:2396 - Unable to mount
> > 10.129.155.101:/vol/secondary at
> > /mnt/SecStorage/548477a5-73f6-3dd6-9179-93e4c92a3329 due to mount.nfs:
> > Connection timed out
>
>
> And here the log shows timeouts.
>
>
> > Also on public interface & Storage interface,are not trunk.Only
> inter-vlan
> > routing is enable.
>
>
> Have you checked if the SSVM’s virtual interfaces got bridged to the
> physical
> interfaces as per your label scheme? Have you run tcpdump to see if the
> packets are going over the right interface? Can you snoop on the switch
> end to
> see if the packets are indeed making it out the interface? Are the switches
> configured with VLANs correctly?
>
>
> >
> >
> > Regards,
> > Tejas
> >
> >
> >
> > On Thu, Jun 5, 2014 at 11:40 AM, Shanker Balan <
> shanker.ba...@shapeblue.com>
> > wrote:
> >
> >> Hi Tejas,
> >>
> >> comments inline.
> >>
> >> On 04-Jun-2014, at 1:09 pm, Tejas Gadaria <refond.g...@gmail.com>
> wrote:
> >>
> >>> Hi,
> >>>
> >>> I am trying to create setup with xenserver, where Storage,public,Guest
> &
> >>> Management traffic will be carried by 4 diff. nics & all are in
> different
> >>> VLAN.
> >>> After assigning the name-label in xen. System vm's are created but I am
> >> not
> >>> able ping to SSVM & CPVM public IP .
> >>>
> >>> root@s-1-VM:~# route
> >>> Kernel IP routing table
> >>> Destination     Gateway         Genmask         Flags Metric Ref    Use
> >>> Iface
> >>> default         10.129.152.1    0.0.0.0         UG    0      0        0
> >> eth2
> >>> google-public-d 10.129.151.1    255.255.255.255 UGH   0      0        0
> >> eth1
> >>> 10.129.151.0    *               255.255.255.0   U     0      0        0
> >> eth1
> >>> 10.129.152.0    *               255.255.255.0   U     0      0        0
> >> eth2
> >>> 10.129.155.0    *               255.255.255.0   U     0      0        0
> >> eth3
> >>> link-local      *               255.255.0.0     U     0      0        0
> >> eth0
> >>>
> >>> root@s-1-VM:~# ping 8.8.8.8
> >>> PING 8.8.8.8 (8.8.8.8): 48 data bytes
> >>> 56 bytes from 8.8.8.8: icmp_seq=0 ttl=46 time=64.948 ms
> >>> ^C--- 8.8.8.8 ping statistics ---
> >>> 1 packets transmitted, 1 packets received, 0% packet loss
> >>> round-trip min/avg/max/stddev = 64.948/64.948/64.948/0.000 ms
> >>
> >> You are able to reach Google DNS because there is a static
> >> route to 8.8.8.8 via the management subnet.
> >>
> >>
> >>> I am not able to ping to Storage from SSVM either.
> >>>
> >>> Following below link right now.
> >>>
> >>
> https://cwiki.apache.org/confluence/display/CLOUDSTACK/SSVM%2C+templates%2C+Secondary+storage+troubleshooting
> >>
> >>
> >> Can share the full output of ssvm-check.sh?
> >>
> >> Can you ping the gateway? If not, it could be that:
> >>
> >> 1) 10.129.152.0 subnet is not routable or cant reach 10.129.152.1
> >> 2) eth2 is bridged to the interfaces labeled for public traffic
> >>
> >> I would check if each of the virtual interfaces are bridged to the right
> >> physical interface on the XenServer labeled interfaces.
> >>
> >> tcpdump on all the interfaces on the SSVM and on the physical
> >> interfaces will also help identify the issue.
> >>
> >> Regards.
> >>
> >> --
> >> @shankerbalan
>
> --
> @shankerbalan
>
> M: +91 98860 60539 | O: +91 (80) 67935867
> shanker.ba...@shapeblue.com | www.shapeblue.com | Twitter:@shapeblue
> ShapeBlue Services India LLP, 22nd floor, Unit 2201A, World Trade Centre,
> Bangalore - 560 055
>
> Find out more about ShapeBlue and our range of CloudStack related services
>
> IaaS Cloud Design & Build<
> http://shapeblue.com/iaas-cloud-design-and-build//>
> CSForge – rapid IaaS deployment framework<http://shapeblue.com/csforge/>
> CloudStack Consulting<http://shapeblue.com/cloudstack-consultancy/>
> CloudStack Infrastructure Support<
> http://shapeblue.com/cloudstack-infrastructure-support/>
> CloudStack Bootcamp Training Courses<
> http://shapeblue.com/cloudstack-training/>
>
> This email and any attachments to it may be confidential and are intended
> solely for the use of the individual to whom it is addressed. Any views or
> opinions expressed are solely those of the author and do not necessarily
> represent those of Shape Blue Ltd or related companies. If you are not the
> intended recipient of this email, you must neither take any action based
> upon its contents, nor copy or show it to anyone. Please contact the sender
> if you believe you have received this email in error. Shape Blue Ltd is a
> company incorporated in England & Wales. ShapeBlue Services India LLP is a
> company incorporated in India and is operated under license from Shape Blue
> Ltd. Shape Blue Brasil Consultoria Ltda is a company incorporated in Brasil
> and is operated under license from Shape Blue Ltd. ShapeBlue is a
> registered trademark.
>

Reply via email to