Thanks for the sharing

-Wei

On Fri, May 16, 2025 at 9:43 AM Jürgen Gotteswinter
<juergen.gotteswin...@mgm-tp.com.invalid> wrote:

> For the records, this is not related to acs. Setting the correct Mysql
> version in ProxySQL helps: set mysql-server_version='8.0.40-31.1';
>
> Am 15.05.25, 17:24 schrieb "Jürgen Gotteswinter"
> <juergen.gotteswin...@mgm-tp.com.inva <mailto:
> juergen.gotteswin...@mgm-tp.com.inva>LID>:
>
>
> Hello,
>
>
> I am trying to setup proxysql in front of our acs management galera
> cluster. Without proxysql everything is working fine. ProxySQL
> configuration also seems to be fine, I can connect via mysql cli without
> problems. But if the ACS Management starts and tries to connect to the
> database, I am getting a proxysql error:
>
> 2025-05-15 15:08:15
> MySQL_Session.cpp:4608:handler_minus1_LogErrorDuringQuery(): [WARNING]
> Error during query on (1,10.xx.x.15,3306,177354): 1193, Unknown system
> variable 'query_cache_size'
>
> Does anyone have a hint what acs is doing here? Query_cache_size was
> removed in 8.0
>
>
> Thanks!
>
>
> Juergen
>
>
>
>