On 06/08/16 07:33 PM, Dan Swartzendruber wrote: > > Okay, I almost have this all working. fence_ipmilan for the supermicro > host. Had to specify lanplus for it to work. fence_drac5 for the R905. > That was failing to complete due to timeout. Found a couple of helpful > posts that recommended increase the retry count to 3 and the timeout to > 60. That worked also. The only problem now, is that it takes well over > a minute to complete the fencing operation. In that interim, the fenced > host shows as UNCLEAN (offline), and because the fencing operation > hasn't completed, the other node has to wait to import the pool and > share out the filesystem. This causes the vsphere hosts to declare the > NFS datastore down. I hadn't gotten exact timing, but I think the > fencing operation took a little over a minute. I'm wondering if I could > change the timeout to a smaller value, but increase the retries? Like > back to the default 20 second timeout, but change retries from 1 to 5?
Did you try the fence_ipmilan against the DRAC? It *should* work. Would be interesting to see if it had the same issue. Can you check the DRAC's host's power state using ipmitool directly without delay? -- Digimer Papers and Projects: https://alteeve.ca/w/ What if the cure for cancer is trapped in the mind of a person without access to education? _______________________________________________ Users mailing list: Users@clusterlabs.org http://clusterlabs.org/mailman/listinfo/users Project Home: http://www.clusterlabs.org Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf Bugs: http://bugs.clusterlabs.org