On 26/11/2023 10:32, lejeczek via Users wrote:
Hi guys.
With these:
-> $ pcs resource status REDIS-6381-clone
* Clone Set: REDIS-6381-clone [REDIS-6381] (promotable):
* Promoted: [ ubusrv2 ]
* Unpromoted: [ ubusrv1 ubusrv3 ]
-> $ pcs resource status PGSQL-PAF-5433-clone
* Clone Set: PGSQL-PAF-5433-clone [PGSQL-PAF-5433]
(promotable):
* Promoted: [ ubusrv1 ]
* Unpromoted: [ ubusrv2 ubusrv3 ]
-> $ pcs constraint ref REDIS-6381-clone
Resource: REDIS-6381-clone
colocation-REDIS-6381-clone-PGSQL-PAF-5433-clone-INFINITY
basically promoted Redis should follow promoted pgSQL but
it's not happening, usually it does.
I presume pcs/cluster does something internally which
results in disobeying/ignoring that _colocation_
constraint for these resources.
I presume scoring might play a role:
REDIS-6385-clone with PGSQL-PAF-5435-clone (score:1001)
(rsc-role:Master) (with-rsc-role:Master)
but usually, that scoring works, only "now" it does not.
Any comments I appreciate much.
thanks, L.
I looked at pamaker log - snippet below after
REDIS-6381-clone re-enabled - but cannot see explanation
for this.
...
notice: Calculated transition 110, saving inputs in
/var/lib/pacemaker/pengine/pe-input-3729.bz2
notice: Transition 110 (Complete=0, Pending=0, Fired=0,
Skipped=0, Incomplete=0,
Source=/var/lib/pacemaker/pengine/pe-input-3729.bz2): Complete
notice: State transition S_TRANSITION_ENGINE -> S_IDLE
notice: State transition S_IDLE -> S_POLICY_ENGINE
notice: Actions: Start REDIS-6381:0
( ubusrv2 )
notice: Actions: Start REDIS-6381:1
( ubusrv3 )
notice: Actions: Start REDIS-6381:2
( ubusrv1 )
notice: Calculated transition 111, saving inputs in
/var/lib/pacemaker/pengine/pe-input-3730.bz2
notice: Initiating start operation REDIS-6381_start_0
locally on ubusrv2
notice: Requesting local execution of start operation for
REDIS-6381 on ubusrv2
(to redis) root on none
pam_unix(su:session): session opened for user
redis(uid=127) by (uid=0)
pam_sss(su:session): Request to sssd failed. Connection
refused
pam_unix(su:session): session closed for user redis
pam_sss(su:session): Request to sssd failed. Connection
refused
notice: Setting master-REDIS-6381[ubusrv2]: (unset) -> 1000
notice: Transition 111 aborted by
status-2-master-REDIS-6381 doing create
master-REDIS-6381=1000: Transient attribute change
INFO: demote: Setting master to 'no-such-master'
notice: Result of start operation for REDIS-6381 on
ubusrv2: ok
notice: Transition 111 (Complete=4, Pending=0, Fired=0,
Skipped=1, Incomplete=14,
Source=/var/lib/pacemaker/pengine/pe-input-3730.bz2): Stopped
notice: Actions: Promote REDIS-6381:0 (
Unpromoted -> Promoted ubusrv2 )
notice: Actions: Start REDIS-6381:1
( ubusrv1 )
notice: Actions: Start REDIS-6381:2
( ubusrv3 )
notice: Calculated transition 112, saving inputs in
/var/lib/pacemaker/pengine/pe-input-3731.bz2
notice: Initiating notify operation
REDIS-6381_pre_notify_start_0 locally on ubusrv2
notice: Requesting local execution of notify operation
for REDIS-6381 on ubusrv2
notice: Result of notify operation for REDIS-6381 on
ubusrv2: ok
notice: Initiating start operation REDIS-6381_start_0 on
ubusrv1
notice: Initiating start operation REDIS-6381:2_start_0
on ubusrv3
notice: Initiating notify operation
REDIS-6381_post_notify_start_0 locally on ubusrv2
notice: Requesting local execution of notify operation
for REDIS-6381 on ubusrv2
notice: Initiating notify operation
REDIS-6381_post_notify_start_0 on ubusrv1
notice: Initiating notify operation
REDIS-6381:2_post_notify_start_0 on ubusrv3
notice: Result of notify operation for REDIS-6381 on
ubusrv2: ok
notice: Initiating notify operation
REDIS-6381_pre_notify_promote_0 locally on ubusrv2
notice: Requesting local execution of notify operation
for REDIS-6381 on ubusrv2
notice: Initiating notify operation
REDIS-6381_pre_notify_promote_0 on ubusrv1
notice: Initiating notify operation
REDIS-6381:2_pre_notify_promote_0 on ubusrv3
notice: Result of notify operation for REDIS-6381 on
ubusrv2: ok
notice: Initiating promote operation REDIS-6381_promote_0
locally on ubusrv2
notice: Requesting local execution of promote operation
for REDIS-6381 on ubusrv2
notice: Result of promote operation for REDIS-6381 on
ubusrv2: ok
notice: Initiating notify operation
REDIS-6381_post_notify_promote_0 locally on ubusrv2
notice: Requesting local execution of notify operation
for REDIS-6381 on ubusrv2
notice: Initiating notify operation
REDIS-6381_post_notify_promote_0 on ubusrv1
notice: Initiating notify operation
REDIS-6381:2_post_notify_promote_0 on ubusrv3
notice: Result of notify operation for REDIS-6381 on
ubusrv2: ok
notice: Setting master-REDIS-6381[ubusrv3]: (unset) -> 1
notice: Transition 112 aborted by
status-3-master-REDIS-6381 doing create
master-REDIS-6381=1: Transient attribute change
notice: Setting master-REDIS-6381[ubusrv1]: (unset) -> 1
notice: Transition 112 (Complete=25, Pending=0, Fired=0,
Skipped=5, Incomplete=5,
Source=/var/lib/pacemaker/pengine/pe-input-3731.bz2): Stopped
notice: Calculated transition 113, saving inputs in
/var/lib/pacemaker/pengine/pe-input-3732.bz2
notice: Initiating monitor operation
REDIS-6381_monitor_20000 locally on ubusrv2
notice: Requesting local execution of monitor operation
for REDIS-6381 on ubusrv2
notice: Initiating monitor operation
REDIS-6381_monitor_60000 on ubusrv3
notice: Initiating monitor operation
REDIS-6381_monitor_45000 on ubusrv3
notice: Initiating monitor operation
REDIS-6381_monitor_60000 on ubusrv1
notice: Initiating monitor operation
REDIS-6381_monitor_45000 on ubusrv1
notice: Result of monitor operation for REDIS-6381 on
ubusrv2: promoted
notice: Transition 113 (Complete=5, Pending=0, Fired=0,
Skipped=0, Incomplete=0,
Source=/var/lib/pacemaker/pengine/pe-input-3732.bz2): Complete
notice: State transition S_TRANSITION_ENGINE -> S_IDLE
To clarify & answer this one question - redis resource move
_promoted_ manually just fine, thus it's not Redis itself.
Here are node attrs. Seem that cluster insists _ubusrv2_ is
somewhat special/different (for some resources?):
Node Attributes:
* Node: ubusrv1 (1):
* master-PGSQL-PAF-5433 : 1000
* master-PGSQL-PAF-5435 : 1000
* master-REDIS : 1
* master-REDIS-6380 : 1
* master-REDIS-6382 : 1
* master-REDIS-6385 : 2
* Node: ubusrv2 (2):
* master-PGSQL-PAF-5433 : 990
* master-PGSQL-PAF-5435 : 1001
* master-REDIS : 1000
* master-REDIS-6380 : 1000
* master-REDIS-6382 : 1000
* master-REDIS-6385 : 2
* Node: ubusrv3 (3):
* master-PGSQL-PAF-5433 : 1001
* master-PGSQL-PAF-5435 : 990
* master-REDIS : 1
* master-REDIS-6380 : 1
* master-REDIS-6382 : 1
* master-REDIS-6385 : 2
Is there a doc/manpage where more about those is explained?
thanks, L.