On Tue, May 28, 2024 at 10:40 AM Александр Руденко <a.rud...@gmail.com> wrote:
> Hi! > > I can't understand this strange behavior, help me please. > > I have 3 nodes in my cluster, 4 vCPU/8GB RAM each. And about 70 groups, 2 > resources in each group. First one resource is our custom resource which > configures Linux VRF and second one is systemd unit. Everything works fine. > > We have next defaults: > pcs resource defaults > Meta Attrs: rsc_defaults-meta_attributes > resource-stickiness=100 > > When I shutdown pacemaker service on NODE1, all the resources move to > NODE2 and NODE3, it's okay. But when I start pacemaker service on NODE1, 3 > of 70 groups move back to NODE1. > But I expect that no one resource will be moved back to NODE1. > > I tried to set resource-stickiness=100 exactly for these 3 groups, but it > didn't help. > > pcs resource config fsmt-41CC55C0 > Group: fsmt-41CC55C0 > Meta Attrs: resource-stickiness=100 > ... > > Why are these 3 resource groups moving back? > Did you check if the 3 groups were really started successfully on NODE2, NODE3 - no failing monitors or something? Did you check for left over infinity location constraints? Klaus > > > _______________________________________________ > Manage your subscription: > https://lists.clusterlabs.org/mailman/listinfo/users > > ClusterLabs home: https://www.clusterlabs.org/ >