Hi all,

I am using the async API to install flow rules to perform the QUEUE action to 
capture packets matching a certain pattern for processing by a DPDK 
application. The ConnectX-6 NIC is configured in multiport e-switch mode, as 
outlined in the documentation 
(https://doc.dpdk.org/guides/nics/mlx5.html#multiport-e-switch). Currently, I 
am facing an issue where I cannot create the corresponding templates for this 
purpose. The command to start test-pmd and create pattern and action templates 
are as follows:

<Command to start test-pmd>
sudo ./dpdk-testpmd -a 3b:00.0,dv_flow_en=2,representor=pf0-1vf0 -- -i --rxq=1 
--txq=1 --flow-isolate-all
</Command to start test-pmd>

<Not working test-pmd commands>
port stop all
flow configure 0 queues_number 1 queues_size 10 counters_number 0 
aging_counters_number 0 meters_number 0 flags 0
flow configure 1 queues_number 1 queues_size 10 counters_number 0 
aging_counters_number 0 meters_number 0 flags 0
flow configure 2 queues_number 1 queues_size 10 counters_number 0 
aging_counters_number 0 meters_number 0 flags 0
flow configure 3 queues_number 1 queues_size 10 counters_number 0 
aging_counters_number 0 meters_number 0 flags 0
port start all

flow pattern_template 0 create transfer relaxed no pattern_template_id 10  
template represented_port ethdev_port_id is 0 / eth type is 0x86dd  / end
flow actions_template 0 create ingress  actions_template_id 10  template queue 
/ end mask queue index 0xffff / end
flow template_table 0 create  group 0 priority 0  transfer wire_orig table_id 5 
rules_number 8 pattern_template 10 actions_template 10
flow queue 0 create 0 template_table 5 pattern_template 0 actions_template 0 
postpone no pattern represented_port ethdev_port_id is 0 / eth type is 0x86dd  
/ end actions queue index 0 / end
flow push 0 queue 0
</Not working test-pmd commands>

The error encountered during the execution of the above test-pmd commands is:

<Encounted error>
mlx5_net: [mlx5dr_action_print_combo]: Invalid action_type sequence
mlx5_net: [mlx5dr_action_print_combo]: TIR
mlx5_net: [mlx5dr_matcher_check_and_process_at]: Invalid combination in action 
template
mlx5_net: [mlx5dr_matcher_bind_at]: Invalid at 0
</Encounted error>

Upon closer inspection of the driver code in DPDK 23.11 (also  the latest DPDK 
main branch), it appears that the error is due to the fact that 
MLX5DR_ACTION_TYP_TIR is not listed as a valid action in the 
MLX5DR_TABLE_TYPE_FDB field. If the following patch is applied, the error is 
resolved, and the DPDK application is able to capture matching packets:

<patch to apply>
diff --git a/drivers/net/mlx5/hws/mlx5dr_action.c 
b/drivers/net/mlx5/hws/mlx5dr_action.c
index 862ee3e332..c444ec761e 100644
--- a/drivers/net/mlx5/hws/mlx5dr_action.c
+++ b/drivers/net/mlx5/hws/mlx5dr_action.c
@@ -85,6 +85,7 @@ static const uint32_t 
action_order_arr[MLX5DR_TABLE_TYPE_MAX][MLX5DR_ACTION_TYP_
                BIT(MLX5DR_ACTION_TYP_VPORT) |
                BIT(MLX5DR_ACTION_TYP_DROP) |
                BIT(MLX5DR_ACTION_TYP_DEST_ROOT) |
+               BIT(MLX5DR_ACTION_TYP_TIR) |
                BIT(MLX5DR_ACTION_TYP_DEST_ARRAY),
                BIT(MLX5DR_ACTION_TYP_LAST),
        },
</patch to apply>

I would greatly appreciate it if anyone could provide insight into whether this 
behavior is intentional or if it is a bug in the driver. Many thanks in advance.
Best regards,
Tao