Hi,

I'm seeing an issue previously mentioned on this list in 2022, where my 
Mellanox NIC is logging an Unexpected CEQ error syndrome. Once this condition 
is hit, the 
rxq->err_state var in the mlx5 PMD is never cleared, and the rx just loops 
around never receiving any further packets. 

It's not clear what's causing the initial CEQ error, as it can take upwards of 
an hour to occur.

The full log entry is:

Unexpected CQE error syndrome 0x04 CQN = 256 SQN = 4679 wqe_counter = 2149 
wq_ci = 3294 cq_ci = 42609
MLX5 Error CQ: at [0x292d26000], len=16384

The NIC is:  NVIDIA ConnectX-7 HHHL Adapter card, 400GbE / NDR IB (default 
mode), Single-port OSFP, PCIe 5.0 x16, Crypto Enabled, Secure Boot Enabled
Part number: MCX75310AAC-NEA_Ax
Firmware: 28.36.1010
OFED Version: 24.04-0.6.6.0
DPDK Version: 23.11.0

This issue was previously mentioned in this post: 
https://mails.dpdk.org/archives/users/2022-October/006779.html

Can anyone please help shed some light on this?

Thanks,
Ken AndrewsKen Andrews R&D Departmentt: +44 1506 671416e: 