Good day gridengine users,

it seems that the issue has been solved - in the end it was only
necessary to start "sge_execd" after "nscd".  I still don't quite
understand why the execd dies only when the first job is started
and not directly after startup.  By that time the nscd has already
been running for a while.  It shouldn't die at all anyway though.

Erik Soyez.


On Tue, 24 May 2011, Erik Soyez wrote:

Good evening,

does anyone else experience dying sge_execds during job starts?
We get error messages "execd went down during job start" but cannot
find any reason.  Little test jobs usually do fine and if the execd
gets restarted manually it seems to keep running, too.  Ideas?


--

--