Greeting,

I set  ACC_RESERVED_USAGE=true  and  job_is_first_task=true on PE. (first
config)

result on accounting for
ru_wallclock 2
slots        20
cpu          60.000

 this is not on my except!

then I changed job_is_first_task=false and results of accounting are:

ru_wallclock 2
slots        20
cpu          42.000

this is on my except.

Why at  first config above, wallclock added 1 and multiuplied with slots?
_______________________________________________
users mailing list
[email protected]
https://gridengine.org/mailman/listinfo/users

Reply via email to