Hello Reuti,

>> Is there a way I can tell SGE that there are only 16 endpoints on a
>> node, so it would not allocate more than 16 MPI processes to a single
>> node?  (This seems to call for per-node consumable, which AFAIK do not
>> exist.)
>
> Sure they exist. Just define a consumable complex and attach it to
> each exehost `qconf - me node001`… in the entry "complex_values".

Thank you very much!  I really do not know why I was convinced that
the basic application of complex values would not work here...

Kind regards,
Riccardo

--
Riccardo Murri
http://www.s3it.uzh.ch/about/team/

S3IT: Services and Support for Science IT
University of Zurich
Winterthurerstrasse 190, CH-8057 Zürich (Switzerland)
Tel: +41 44 635 4222
Fax: +41 44 635 6888

_______________________________________________
users mailing list
[email protected]
https://gridengine.org/mailman/listinfo/users

Reply via email to