On Thu, Jun 16, 2016 at 02:40:00PM +0300, Laurence Mayer wrote:
>    We are currently using qsub -sync and often see the below error, a rerun
>    of succeeds :
>         Unable to wait for job because of error: Event client got shutdown
>    signal.
>            Exiting.
>    However we don't see any connectivity or other related issues on the
>    Server running the SGE Master.
>    Can anyone provide guidance to resolve this issue?
>    Thanks
>    Laurence
Do you get this message immediately on submitting the job or at some later time?

Is there any evidence of activity concerning the job in the logs?  Perhaps
the job is being scheduled to a node that is misbehaving and that is somehow 
provoking the shutdown signal.

William