Hi all I have to connect to one cell operartor that is asking me to make one connection per shortnumber:
Information for connecting: --------------------------------------- (Shortcode 1234) IP: aaa.bbb.ccc.ddd Port: 4000 *Source: 1234* System ID: uuuu Password: pppp System Type: smpp Source TON: 2 Source NPI: 1 Destination TON: 2 Destination NPI: 1 One bind for Rx, and one bind for Tx. --------------------------------------- My conf is like: group = smsc smsc = smpp smsc-id = carrier1 allowed-smsc-id = "carrier1" host = aaa.bbb.ccc.ddd port = 4000 receive-port = 4000 smsc-username = "uuuu" smsc-password = pppp system-type = "smpp" reconnect-delay = 10 address-range = "" connect-allow-ip = aaa.bbb.ccc.ddd source-addr-ton = 2 source-addr-npi = 1 dest-addr-ton = 2 dest-addr-npi = 1 But, I need to connec for short number 1234 and 5678 1) How can I tell kannel that a connection is for certain short number? 2) What "One bind for Rx, and one bind for Tx." means? That I have to set: port = 4000 receive-port = 4000 ??? Thanks in advance Regards Diego