Hello List, I'm using Kannel version 1.4.1 on EMI/UCP protocol. I'm already using DLR - however the ACK/ or NACK/ comes from the SMS G/W and not from the Operator SMSC In order to check if the message was received by the user I need to implement "Delivery notification operation -53" UCP-53.
I was guided by the SMS G/W integrators - to change the following parameters Nrq Notification Request set with value "1" NT Notification Type set with value "3" See 1 and 3 after the largeaccount (short code number) .07/00347/O/51/msisdn/largeaccount//1//3////////0000/////4/904/024A3A6DB9BD7DBDB9957DB5BDB9BC04009916A65AB6551649A2D9845A2A8B86916CC30AB2C9365A2AC26CB2447708C2D138592B0B459B6CB32D1561661541365B2292A8B44D061055170D22D9865A2AC26C2AC26CB6446461689C0AC2D966DA2CC2AC2CCB6551689B0AB2C9365A226000///1/1//////010706050415810000FE09323632373338393132///C8 Does anyone knows if Kannel supports this operation, and how to implement it? I was also explained that this query is not in RealTime and I will have to check the status. In return I'm suppose to receive 0 for positive delivery or one of the following error codes: Table B-3: Error Messages and Reason Codes in Notifications Reason Code Meaning 000 Unknown subscriber 001 Service temporary not available 002 Service temporary not available 003 Service temporary not available 004 Service temporary not available 005 Service temporary not available 006 Service temporary not available 007 Service temporary not available 008 Service temporary not available 009 Illegal error code 010 Network time-out 100 Facility not supported 101 Unknown subscriber 102 Facility not provided 103 Call barred 104 Operation barred 105 SC congestion 106 Facility not supported 107 Absent subscriber 108 Delivery fail 109 Sc congestion 110 Protocol error 111 MS not equipped 112 Unknown SC 113 SC congestion 114 Illegal MS 115 MS not a subscriber 116 Error in MS 117 SMS lower layer not provisioned 118 System fail 119 PLMN system failure 120 HLR system failure 121 VLR system failure 122 Previous VLR system failure 123 Controlling MSC system failure 124 VMSC system failure 125 EIR system failure 126 System failure 127 Unexpected data value 200 Error in address service centre 201 Invalid absolute Validity Period 202 Short message exceeds maximum 203 Unable to Unpack GSM message 204 Unable to convert to IRA ALPHABET 205 Invalid validity period format 206 Invalid destination address 207 Duplicate message submit 208 Invalid message type indicator Thanks in advance, Oren Ein-Gal Chief Operating Officer Volas Entertainment | unleash your content T +972 73 252 5252 (ext. 129) F +972 9 956 7481 M + 972 54 522 4183 o...@volasent.com www.VolasEnt.com Part of the LogiaGroup