You should use configarion variable 'throughput' under each of your SMSC: group = smsc smsc = smpp smsc-id = XXX ... ... throughput = 15
Kannel repeats messages from queue by default, if you did not modified configuration. On Fri, Mar 7, 2014 at 5:33 PM, tolis man <[email protected]> wrote: > Hello, > > I would like to know if it's possible to handle some specific errors, like > > 1. 0x58 Throttling Error > 2. 0x14 Message Queue Full > > -- > > There's a requirement saying that when I receive a throttling error > message, the needed behaviour is: > > Stop sending any Submit_sm for 60 seconds. Any more outgoing Submit_sm's > must be placed to the queue. The message, which get an error must be placed > 1st in the queue. > After 60 seconds timeout, continue sending normally, according queue. > > -- > > If I receive a Message Queue Full error, the needed behaviour is: > > Resend message. Try to resend it only 3-5 times. Every time you get an > error, place message at very end of queue. > > -- > > Is it possible to adjust the above with configuration on the smsc group? > > Thank you in advance, > -- Pagarbiai, *Valdas Petrulis* +37067310422 Skype: petrulis.valdas [image: Inline image 1]