On 05/03/2015 05:40 AM, MegaBrutal wrote:
Sorry for reviving a thread from the past, but I have a very similar
problem: my Current_Pending_Sector value is 2, and I get notifications
about it. I'm wondering whether I should replace the drive. What is
strange, though, is that when I run a long self-test (smartctl -t long
/dev/sdc), it reports „Completed without error”. Thus, I can't even
find the addresses of the faulty sectors – and actually, I question
the validity of my S.M.A.R.T. values. Either the
„Current_Pending_Sector” is incorrect (in reality, I have none), or
the self-test was not efficient enough to find the bad sector.

In this case, your guess is as good as mine.  You could try running
"dd if=/dev/sdc of=/dev/null bs=256k" and see if you get any read
errors.  Short of saving the data elsewhere and overwriting the
entire drive with zeros, I don't have anything to suggest.

--
Bob Nichols     "NOSPAM" is really part of my email address.
                Do NOT delete it.

--
users mailing list
users@lists.fedoraproject.org
To unsubscribe or change subscription options:
https://admin.fedoraproject.org/mailman/listinfo/users
Fedora Code of Conduct: http://fedoraproject.org/code-of-conduct
Guidelines: http://fedoraproject.org/wiki/Mailing_list_guidelines
Have a question? Ask away: http://ask.fedoraproject.org

Reply via email to