Hello,
In my envruent I use two qfx5100 in VC, and there is a problem with working 
ovsdb. I think junos version 14.1x53-d26.2 is not ready to work with VC. 
Anybody knows when will be released version of junos ready to work with VC? My 
CN use bonding in A-S mode where one of the interface is used for ip-fabric and 
second one is used for sorage.

Pozdrawiam
TomekC




On Fri, Jul 10, 2015 at 6:33 AM -0700, "Dan Houtz" <[email protected]> wrote:










Hi,
Is anyone currently doing redundant connectivity to bare metal servers? Our 
initial thought was that we would do two top of rack QFX running MC-LAG so our 
servers could run LACP to both of them however MC-LAG is not currently 
supported with VXLAN (I'm told it's on the roadmap). I suspect virtual chassis 
would allow us do to this but haven't tested and honestly we don't really want 
to stack the switches. I guess the other potential option is to just drop both 
of the server's nic ports in a VNI and not run any intelligence protocols 
though this doesn't seem like the proper way to do it :)
Would definitely be interested in other people's experiences if this is being 
done.
Thanks!Dan