Hello Alexey

You are right. I did that for the moment. So I do topology hiding with C option 
when a communication enters my infra and then just topology hiding without C 
until it exit.

Thank you for pointing this.

My suggestion is still on the table. 


Antonis Psaras

-----Original Message-----
From: Users <[email protected]> On Behalf Of Alexey
Sent: Παρασκευή, 9 Μαΐου 2025 09:54
To: OpenSIPS users mailling list <[email protected]>
Subject: Re: [OpenSIPS-Users] CallID shorting

Hi all,

maybe I'm mistaken, but what if just not to use the "C"
option of the "topology_hiding()" [1] function?

If it is optional - to encode the callid header - maybe you can skip this, and 
the problem will be solved?

[1] 
https://opensips.org/docs/modules/3.5.x/topology_hiding.html#func_topology_hiding

--
best regards, Alexey
https://alexeyka.zantsev.com/