Hi,
The only thing you can do is (1) ask the carrier for an example of such
bogus dialog and (2) investigate the SIP traffic to be sure that the BYE
exchange with the carrier was correctly done...
Regards,
Bogdan-Andrei Iancu
OpenSIPS Founder and Developer
https://www.opensips-solutions.com
https://www.siphub.com
On 27.06.2025 00:57, Federico Alves wrote:
So far my engineers use topology_hiding(), and the CallID from the
client was passing forward to the carrrier. So we switched to
topology_hiding("C") and worked as expected but the carrier's switch
collapsed after a while. They say that we leave many dialogs open thar
never close. Other than that, th3 calls work fine for us.
What are my engineers doing wrong?
_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users
_______________________________________________
Users mailing list
[email protected]
http://lists.opensips.org/cgi-bin/mailman/listinfo/users